I-55 8 OUTPUTS SEQUENTIAL
Reference: I-55
Power supply: 12 V. DC.
Minimum/maximum consumption: 20 mA / 70 mA.
Time setting scale A : 1 second to 100 seconds
Time setting scale B : 1 min to 100 min.
Output configuration: 1 to 8 relays
Inputs: INC, PAUSE, RESET
max Output load: 7A (2A for inductive loads)
Operation indicator led: relays, DC power supply
Protection against reverse polarity: Yes.
Measurements: 107 x 155 x 22 mm.
Weight : 157 grams
DIN rail : C-7592
Sequential with 8 relay outputs, which allow any type of load.
For each impulse received, the module will connect one output after another, disconnecting the previous ones, and restarting after connecting the last one.
It allows manual operation with a button or automatic with the internal timer, with time adjustment in seconds or minutes scale.
It incorporates button, pause and reset inputs, output indicator leds, protection against polarity inversion and connection terminals.
Recommended power supply FE-103